Certificates of permanent & temporary structures
All 16.3/400 P3N, 20.3/400 P3N, 30.4/400 P2N permanent & temporary space solutions and pagodas are built and designed in accordance with German building regulations under the supervision of German technical services and meet an estimated minimum resistance in wind of the order of 100 km/h including safety factor: 1.5. During strong winds of the order of 75 kilometers per hour the doors of halls and awnings must remain closed and not open to avoid internal pressure.
Fire resistance: The fabric parts of the aforementioned constructions are flame retardant according to, among others, DIN 4102 B1, M2 standards.
Maximum snow load: During periods of possible snowfall, the top of the structure should be heated to 12 degrees Celsius to prevent snow accumulation on the roof.
Maximum floating loads:
16.4/400 = 1000 kg per roof support in total (with a maximum suspended load of 500 kg per point)
20.3/400 = 900 kg per roof bracket in total (with a maximum suspended load of 450 kg per point)
30.4/400 = 700 kg per roof support in total (with a maximum suspended load of 300 kg per point)
PVC Flammability Certificate:
FIRE TECHNOLOGY SERVICES
Department of BTTG Testing & Certification Ltd
Reference code: FerrariS.A.
PVC coated polyester fabric, refers to Precontraint 702 opaque.
Specimen BS 7837: 1696
Test Method: BS 5438: 1989 Test 2B (Bottom End Ignition)
Flame Application Time = 10s, Cut Edge.
Customer-specified face to the burner.